PTI M10.6-15: Specification for Unbonded Single Strand Tendons Used for Slab-on-Ground Construction

Autor:

Descripción

This specification provides performance criteria for materials and detailed recommendations for the fabrication and installation of unbonded single strand tendons


Características

  • Páginas: 35
  • Tamaño: 21x30
  • Edición:
  • Idioma: Inglés
  • Año: 2015

Disponibilidad: 3 a 7 Días

Contenido PTI M10.6-15: Specification for Unbonded Single Strand Tendons Used for Slab-on-Ground Construction

This specification provides performance criteria for materials and detailed recommendations for the fabrication and installation of unbonded single strand tendons specifically used in any application of slab-on-ground construction using unbonded post-tensioned reinforcement. Specifications are presented for both “standard” and “encapsulated” unbonded single-strand tendon systems.

TABLE OF CONTENTS

1.0 — General

1.1 — Scope
1.2 — Definitions
1.3 — References
  1.3.1 — Referenced standards and organizations 4
  1.3.2 — Cited publications
1.4 — System description
1.5 — Submittals
  1.5.1 — Prestressing steel
  1.5.2 — Anchorages and couplers
  1.5.3 — Sheathing
  1.5.4 — PT coating
  1.5.5 — Fabrication plant
  1.5.6 — Stressing records
1.6 — Fabrication
  1.6.1 — General
   1.6.1.1 — PTI certified plants
   1.6.1.2 — Non-PTI certified plants
  1.6.2 — Handling, storage, and shipping
   1.6.2.1 — Handling prior to shipping
   1.6.2.2 — Storage prior to shipping
   1.6.2.3 — Shipping
1.7 — Delivery, handling, and storage
  1.7.1 — Delivery
  1.7.2 — Handling and storage
   1.7.2.1 — Handling
   1.7.2.2 — Storage
   1.7.2.3 — Exposure
   1.7.2.4 — Wedges and anchors
 
2.0 — Products

2.1 — Prestressing steel
   2.1.1 — Mechanical properties
   2.1.2 — Thermomechanical treatment
   2.1.3 — Traceability
   2.1.4 — Testing
   2.1.5 — Strand producer records
   2.1.6 — Identification
   2.1.7 — Packaging, marking, storage,and protection
   2.1.8 — Acceptance criteria for surface condition
   2.1.9 — Compliance requirements
2.2 — Anchorages and couplers
   2.2.1 — Anchorages
    2.2.1.1 — Static tests
    2.2.1.2 — Fatigue tests
    2.2.1.3 — Bearing stresses
   2.2.2 — Castings
   2.2.3 — Wedges used in anchorages
   2.2.4 — Couplers
   2.2.5 — Compliance requirements
    2.2.5.1 — Conformance testing
    2.2.5.2 — Compliance
   2.2.6 — Anchorages and couplers in aggressive environments
    2.2.6.1 — Anchorages
    2.2.6.2 — Encapsulated tendons
2.3 — Sheathing
   2.3.1 — General properties
   2.3.2 — Minimum thickness and diameter
    2.3.2.1 — Minimum thickness
    2.3.2.2 — Inside diameter
    2.3.2.3 — Appearance
   2.3.3 — Fabrication process
   2.3.4 — Sheathing coverage
   2.3.5 — Encapsulated tendons
2.4 — PT coating
   2.4.1 — General properties
   2.4.2 — Type of PT coating
   2.4.3 — Minimum quantity
   2.4.4 — Performance criteria
 
3.0 — Execution

3.1 — General
   3.1.1 — Qualifications and inspection
   3.1.2 — Recommended procedures
    3.1.3 — Handling
    3.1.4 — Protection
3.2 — Tendon installation
   3.2.1 — General
    3.2.1.1 — Support intervals
    3.2.1.2 — Support system
    3.2.1.3 — Tendon tolerances
    3.2.1.4 — Lateral deviations
    3.2.1.5 — Protection
    3.2.1.6 — Protection from water
    3.2.1.7 — Encapsulated tendons
   3.2.2 — Stressing anchorages
    3.2.2.1 — Installation
    3.2.2.2 — Attachment requirements
    3.2.2.3 — Cover requirements
    3.2.2.4 — Pocket formers
    3.2.2.5 — Encapsulated tendons
    3.2.2.6 — Strand tail cover
   3.2.3 — Intermediate anchorages
    3.2.3.1 — Installation
    3.2.3.2 — Placement
    3.2.3.3 — Cover requirements
    3.2.3.4 — Pocket formers
    3.2.3.5 — Encapsulated tendons
   3.2.4 — Fixed anchorages
    3.2.4.1 — Installation
    3.2.4.2 — Wedge seating methodsfor fixed anchorages
    3.2.4.3 — Placement
    3.2.4.4 — Encapsulated tendons
   3.2.5 — Sheathing inspection
    3.2.5.1 — Sheathing damage
    3.2.5.2 — Repair procedure
 3.3 — Concrete placement
   3.3.1 — General
   3.3.2 — Placement
   3.3.3 — Protection of tendons
   3.3.4 — Sheathing repairs
  3.4 — Tendon stressing
   3.4.1 — General
   3.4.1.1 — Protection from water
   3.4.1.2 — Stressing procedures
   3.4.1.3 — Stressing jacks
  3.4.2 — Jack calibration
  3.4.3 — Elongation measurements
3.5 — Tendon finishing
  3.5.1 — General
   3.5.1.1 — Cutting of tendon tails
   3.5.1.2 — Cutting methods
  3.5.2 — Encapsulated tendons
  3.5.3 — Stressing pockets
   3.5.3.1 — Preparation
   3.5.3.2 — Timing
 